Laboratory Environmental Monitoring
Sorun
Labs need stable temperature, humidity and pressure, working fume hoods and alarms on freezers, but each device alarms locally and records are kept on paper.
Çözüme genel bakış
MILESGO gateways collect data from temperature and humidity sensors, differential pressure sensors, fume hood and lab ventilation controllers, refrigerators, freezers and cold room controllers, PT100 / PT1000 temperature probes over Modbus RTU / BACnet MS/TP, and deliver it to the BMS, a historian / database (MySQL, SQL Server, InfluxDB), SMS, email and messaging alarms as BACnet/IP / MQTT. Field equipment keeps its own protocol and control logic; integration is done by configuration and point mapping, not custom code.
Typical scope
- temperature and humidity sensors
- differential pressure sensors
- fume hood and lab ventilation controllers
- refrigerators, freezers and cold room controllers
- PT100 / PT1000 temperature probes
Protocol path
Modbus RTU / BACnet MS/TP → BACnet/IP / MQTT
Implementation checklist for the project manager
- Keep sensor calibration certificates on file and plan recalibration intervals.
- Agree data retention and the report format needed for audits with the quality team at the start.
- Agree sensor positions (height, airflow, distance from doors and diffusers) so readings are representative.
- Define an alarm matrix (priority, recipient, escalation) and test every alarm end to end at SAT.
- For hard-wired signals, list each DI/DO/AI/AO with its type (dry contact, 4–20 mA, 0–10 V, PT1000) and choose I/O modules accordingly.
- Confirm local storage so data survives network outages, and define the retention period.
Project deliverables
- Signed point table and protocol mapping
- Gateway configuration files and backups
- IP address plan and network drawing
- FAT and SAT test records
- As-built documentation and operator training
Sistem mimarisi
Field layer: temperature and humidity sensors, differential pressure sensors, fume hood and lab ventilation controllers, refrigerators, freezers and cold room controllers, PT100 / PT1000 temperature probes, connected over Modbus RTU / BACnet MS/TP. Edge and integration layer: MILESGO protocol gateways and edge controllers, mounted on DIN rail in existing panels, polling each device, time-stamping values and buffering them locally. Upper layer: the BMS, a historian / database (MySQL, SQL Server, InfluxDB), SMS, email and messaging alarms, which receives the data as BACnet/IP / MQTT. Remote access for maintenance runs over VPN rather than open internet ports.
Sistem bileşenleri
- Field devices
- temperature and humidity sensors, differential pressure sensors, fume hood and lab ventilation controllers, refrigerators, freezers and cold room controllers, PT100 / PT1000 temperature probes
- Edge / integration
- MILESGO protocol gateways and edge controllers
- Upper systems
- the BMS, a historian / database (MySQL, SQL Server, InfluxDB), SMS, email and messaging alarms (BACnet/IP / MQTT)
- Tools and commissioning
- Web-based configuration, point table import/export (Excel), off-site simulation and on-site diagnostic tools
Yazılım ve yapay zekâ yetenekleri
- Anomaly detection on trend dataYol haritasında
Teslimat adımları
- 1
Site survey and point list
Inventory devices, protocols, register maps, panel space, power and network paths.
- 2
Design and point table sign-off
Map every point to the target protocol and system; agree it with the client and the upper-system contractor.
- 3
Configuration and FAT
Build the gateway configuration off site, simulate it and test against the signed point table.
- 4
Installation and wiring
Mount gateways on DIN rail, wire RS-485 / I/O / Ethernet, apply the IP plan.
- 5
SAT and alarm tests
Verify values against local readings, test every alarm and command end to end.
- 6
Handover and support
Hand over configuration backups, point table and as-built documents; train operators.
Müşteriye sağlanan değer
- Timestamped records for compliance and reporting
- Alarms reach the right person by SMS, email or messaging apps
- Abnormal conditions seen early, before they become failures
- One view of all subsystems instead of separate vendor consoles