MILESGO
Yêu cầu báo giá

Water & EnvironmentalS46

Water Network Leakage Detection

Bài toán

Non-revenue water is high but nobody can say in which district it is lost, because inflow meters and night-flow data are not collected per zone.

Tổng quan giải pháp

MILESGO gateways collect data from flow meters, pressure transmitters, water meters, LoRaWAN wireless sensors over Modbus RTU / LoRaWAN / M-Bus, and deliver it to SCADA, a cloud platform (MQTT), a historian / database (MySQL, SQL Server, InfluxDB) as MQTT / OPC UA. Field equipment keeps its own protocol and control logic; integration is done by configuration and point mapping, not custom code.

Typical scope

  • flow meters
  • pressure transmitters
  • water meters
  • LoRaWAN wireless sensors

Protocol path

Modbus RTU / LoRaWAN / M-Bus → MQTT / OPC UA

Implementation checklist for the project manager

  • Configure NTP so trends, alarms and meter readings carry consistent timestamps.
  • Fix a site / asset naming convention before the first site so data from all sites can be compared.
  • Check 4G signal and the SIM data plan at every site before committing to cellular backhaul.
  • Run a LoRaWAN coverage survey and pick the regional band (EU868 / US915 / AU915 / AS923 / KR920 / CN470) before ordering.
  • Confirm local storage so data survives network outages, and define the retention period.
  • Roll out in phases: pilot one site or area, confirm data quality, then replicate.

Project deliverables

  • Signed point table and protocol mapping
  • Gateway configuration files and backups
  • IP address plan and network drawing
  • FAT and SAT test records
  • As-built documentation and operator training

Kiến trúc hệ thống

Field layer: flow meters, pressure transmitters, water meters, LoRaWAN wireless sensors, connected over Modbus RTU / LoRaWAN / M-Bus. Edge and integration layer: MILESGO protocol gateways and edge controllers, mounted on DIN rail in existing panels, polling each device, time-stamping values and buffering them locally. Upper layer: SCADA, a cloud platform (MQTT), a historian / database (MySQL, SQL Server, InfluxDB), which receives the data as MQTT / OPC UA. Remote access for maintenance runs over VPN rather than open internet ports.

Thành phần hệ thống

Field devices
flow meters, pressure transmitters, water meters, LoRaWAN wireless sensors
Edge / integration
MILESGO protocol gateways and edge controllers
Upper systems
SCADA, a cloud platform (MQTT), a historian / database (MySQL, SQL Server, InfluxDB) (MQTT / OPC UA)
Tools and commissioning
Web-based configuration, point table import/export (Excel), off-site simulation and on-site diagnostic tools

Năng lực phần mềm và AI

  • Anomaly detection on trend dataTrong lộ trình
  • Consumption baseline and deviation alertsTrong lộ trình

Các bước triển khai

  1. 1

    Site survey and point list

    Inventory devices, protocols, register maps, panel space, power and network paths.

  2. 2

    Design and point table sign-off

    Map every point to the target protocol and system; agree it with the client and the upper-system contractor.

  3. 3

    Configuration and FAT

    Build the gateway configuration off site, simulate it and test against the signed point table.

  4. 4

    Installation and wiring

    Mount gateways on DIN rail, wire RS-485 / I/O / Ethernet, apply the IP plan.

  5. 5

    SAT and alarm tests

    Verify values against local readings, test every alarm and command end to end.

  6. 6

    Handover and support

    Hand over configuration backups, point table and as-built documents; train operators.

Giá trị cho khách hàng

  • Abnormal conditions seen early, before they become failures
  • Reliable trend data for optimisation and fault diagnosis
  • Manual readings replaced by scheduled automatic collection
  • Data ready for cloud platforms and analytics

Các giải pháp khác trong Water & Environmental

Hãy cho chúng tôi biết về dự án của bạn

Gửi giao thức, số điểm dữ liệu và hệ thống đích. Một nhóm kinh doanh và kỹ thuật sẽ xem xét mọi yêu cầu.

Trao đổi về dự án