Bài toán

Energy is the largest variable cost after materials, but it is only known per month from the utility bill, never per line, shift or product.

Tổng quan giải pháp

MILESGO gateways collect data from electricity meters, gas meters, water meters, steam flow meters, production counters and machine state signals over Modbus RTU / Modbus TCP / M-Bus / S7, and deliver it to the energy management system, MES, large-screen dashboards (HDMI), a cloud platform (MQTT) as OPC UA / MQTT. Field equipment keeps its own protocol and control logic; integration is done by configuration and point mapping, not custom code.

Typical scope

  • electricity meters
  • gas meters
  • water meters
  • steam flow meters
  • production counters and machine state signals

Protocol path

Modbus RTU / Modbus TCP / M-Bus / S7 → OPC UA / MQTT

Implementation checklist for the project manager

  • Record CT ratios, meter IDs and multipliers in the point table; wrong multipliers are the usual cause of billing errors.
  • Agree KPI definitions (for example OEE components or kWh per unit) with operations before building dashboards.
  • Fix a site / asset naming convention before the first site so data from all sites can be compared.
  • Do not modify validated PLC programs; read existing data areas or add gateway-side mapping instead.
  • Configure NTP so trends, alarms and meter readings carry consistent timestamps.
  • Roll out in phases: pilot one site or area, confirm data quality, then replicate.

Project deliverables

  • Signed point table and protocol mapping
  • Gateway configuration files and backups
  • IP address plan and network drawing
  • FAT and SAT test records
  • As-built documentation and operator training

Kiến trúc hệ thống

Field layer: electricity meters, gas meters, water meters, steam flow meters, production counters and machine state signals, connected over Modbus RTU / Modbus TCP / M-Bus / S7. Edge and integration layer: MILESGO protocol gateways and edge controllers, mounted on DIN rail in existing panels, polling each device, time-stamping values and buffering them locally. Upper layer: the energy management system, MES, large-screen dashboards (HDMI), a cloud platform (MQTT), which receives the data as OPC UA / MQTT. Remote access for maintenance runs over VPN rather than open internet ports.

Thành phần hệ thống

Field devices
electricity meters, gas meters, water meters, steam flow meters, production counters and machine state signals
Edge / integration
MILESGO protocol gateways and edge controllers
Upper systems
the energy management system, MES, large-screen dashboards (HDMI), a cloud platform (MQTT) (OPC UA / MQTT)
Tools and commissioning
Web-based configuration, point table import/export (Excel), off-site simulation and on-site diagnostic tools

Năng lực phần mềm và AI

  • Consumption baseline and deviation alertsThí điểm
  • Load and consumption forecastingTrong lộ trình

Các bước triển khai

  1. 1

    Site survey and point list

    Inventory devices, protocols, register maps, panel space, power and network paths.

  2. 2

    Design and point table sign-off

    Map every point to the target protocol and system; agree it with the client and the upper-system contractor.

  3. 3

    Configuration and FAT

    Build the gateway configuration off site, simulate it and test against the signed point table.

  4. 4

    Installation and wiring

    Mount gateways on DIN rail, wire RS-485 / I/O / Ethernet, apply the IP plan.

  5. 5

    SAT and alarm tests

    Verify values against local readings, test every alarm and command end to end.

  6. 6

    Handover and support

    Hand over configuration backups, point table and as-built documents; train operators.

Giá trị cho khách hàng

  • Consumption visible by area, system and time period
  • Consumption attributable by tenant, department or cost centre
  • Reliable trend data for optimisation and fault diagnosis
  • Timestamped records for compliance and reporting

Các giải pháp khác trong Industrial & Manufacturing

Hãy cho chúng tôi biết về dự án của bạn

Gửi giao thức, số điểm dữ liệu và hệ thống đích. Một nhóm kinh doanh và kỹ thuật sẽ xem xét mọi yêu cầu.

Trao đổi về dự án