MILESGO
Teklif İsteyin

Smart BuildingS05

Indoor Air Quality Monitoring

Sorun

Occupants and certification schemes ask for CO2, PM2.5, TVOC and humidity data, but there are no sensors on the BMS, and cabling every floor for them is costly in an occupied building.

Çözüme genel bakış

MILESGO gateways collect data from indoor air quality sensors (CO2, PM2.5, TVOC, T/RH), LoRaWAN wireless sensors, CO2 sensors, air handling units (AHU) over LoRaWAN / Modbus RTU, and deliver it to the BMS, a cloud platform (MQTT), large-screen dashboards (HDMI) as BACnet/IP / MQTT / Modbus TCP. Field equipment keeps its own protocol and control logic; integration is done by configuration and point mapping, not custom code.

Typical scope

  • indoor air quality sensors (CO2, PM2.5, TVOC, T/RH)
  • LoRaWAN wireless sensors
  • CO2 sensors
  • air handling units (AHU)

Protocol path

LoRaWAN / Modbus RTU → BACnet/IP / MQTT / Modbus TCP

Implementation checklist for the project manager

  • Run a LoRaWAN coverage survey and pick the regional band (EU868 / US915 / AU915 / AS923 / KR920 / CN470) before ordering.
  • Agree sensor positions (height, airflow, distance from doors and diffusers) so readings are representative.
  • Keep sensor calibration certificates on file and plan recalibration intervals.
  • Agree BACnet device instances, network numbers and BBMD with the BMS contractor to avoid conflicts.
  • Define an alarm matrix (priority, recipient, escalation) and test every alarm end to end at SAT.
  • Roll out in phases: pilot one site or area, confirm data quality, then replicate.

Project deliverables

  • Signed point table and protocol mapping
  • Gateway configuration files and backups
  • IP address plan and network drawing
  • FAT and SAT test records
  • As-built documentation and operator training

Sistem mimarisi

Field layer: indoor air quality sensors (CO2, PM2.5, TVOC, T/RH), LoRaWAN wireless sensors, CO2 sensors, air handling units (AHU), connected over LoRaWAN / Modbus RTU. Edge and integration layer: MILESGO protocol gateways and edge controllers, mounted on DIN rail in existing panels, polling each device, time-stamping values and buffering them locally. Upper layer: the BMS, a cloud platform (MQTT), large-screen dashboards (HDMI), which receives the data as BACnet/IP / MQTT / Modbus TCP. Remote access for maintenance runs over VPN rather than open internet ports.

Sistem bileşenleri

Field devices
indoor air quality sensors (CO2, PM2.5, TVOC, T/RH), LoRaWAN wireless sensors, CO2 sensors, air handling units (AHU)
Edge / integration
MILESGO protocol gateways and edge controllers
Upper systems
the BMS, a cloud platform (MQTT), large-screen dashboards (HDMI) (BACnet/IP / MQTT / Modbus TCP)
Tools and commissioning
Web-based configuration, point table import/export (Excel), off-site simulation and on-site diagnostic tools

Yazılım ve yapay zekâ yetenekleri

  • Anomaly detection on trend dataYol haritasında
  • Automatic report drafting from collected dataYol haritasında

Teslimat adımları

  1. 1

    Site survey and point list

    Inventory devices, protocols, register maps, panel space, power and network paths.

  2. 2

    Design and point table sign-off

    Map every point to the target protocol and system; agree it with the client and the upper-system contractor.

  3. 3

    Configuration and FAT

    Build the gateway configuration off site, simulate it and test against the signed point table.

  4. 4

    Installation and wiring

    Mount gateways on DIN rail, wire RS-485 / I/O / Ethernet, apply the IP plan.

  5. 5

    SAT and alarm tests

    Verify values against local readings, test every alarm and command end to end.

  6. 6

    Handover and support

    Hand over configuration backups, point table and as-built documents; train operators.

Müşteriye sağlanan değer

  • Reliable trend data for optimisation and fault diagnosis
  • Timestamped records for compliance and reporting
  • Data ready for cloud platforms and analytics
  • Abnormal conditions seen early, before they become failures

Smart Building alanındaki diğer çözümler

Projenizi bize anlatın

Protokolleri, nokta sayısını ve hedef sistemi gönderin. Satış ve mühendislik ekibi her başvuruyu birlikte inceler.

Projenizi Görüşelim