MILESGO
Teklif İsteyin

Energy & PowerS17

Power Quality Monitoring

Sorun

Unexplained trips, harmonics and voltage dips damage equipment, but the analysers that could explain them are only read locally after the event.

Çözüme genel bakış

MILESGO gateways collect data from power quality analysers, electricity meters, protection relays and bay controllers over Modbus RTU / Modbus TCP / IEC 61850, and deliver it to SCADA, the energy management system, SMS, email and messaging alarms as OPC UA / MQTT / BACnet/IP. Field equipment keeps its own protocol and control logic; integration is done by configuration and point mapping, not custom code.

Typical scope

  • power quality analysers
  • electricity meters
  • protection relays and bay controllers

Protocol path

Modbus RTU / Modbus TCP / IEC 61850 → OPC UA / MQTT / BACnet/IP

Implementation checklist for the project manager

  • Collect register maps and protocol documents from every equipment vendor early; a missing map is the most common delay.
  • Configure NTP so trends, alarms and meter readings carry consistent timestamps.
  • Record CT ratios, meter IDs and multipliers in the point table; wrong multipliers are the usual cause of billing errors.
  • Define an alarm matrix (priority, recipient, escalation) and test every alarm end to end at SAT.
  • Confirm local storage so data survives network outages, and define the retention period.
  • Commission in read-only mode first; enable write / control points only after the client approves each one.

Project deliverables

  • Signed point table and protocol mapping
  • Gateway configuration files and backups
  • IP address plan and network drawing
  • FAT and SAT test records
  • As-built documentation and operator training

Sistem mimarisi

Field layer: power quality analysers, electricity meters, protection relays and bay controllers, connected over Modbus RTU / Modbus TCP / IEC 61850. Edge and integration layer: MILESGO protocol gateways and edge controllers, mounted on DIN rail in existing panels, polling each device, time-stamping values and buffering them locally. Upper layer: SCADA, the energy management system, SMS, email and messaging alarms, which receives the data as OPC UA / MQTT / BACnet/IP. Remote access for maintenance runs over VPN rather than open internet ports.

Sistem bileşenleri

Field devices
power quality analysers, electricity meters, protection relays and bay controllers
Edge / integration
MILESGO protocol gateways and edge controllers
Upper systems
SCADA, the energy management system, SMS, email and messaging alarms (OPC UA / MQTT / BACnet/IP)
Tools and commissioning
Web-based configuration, point table import/export (Excel), off-site simulation and on-site diagnostic tools

Yazılım ve yapay zekâ yetenekleri

  • Anomaly detection on trend dataYol haritasında

Teslimat adımları

  1. 1

    Site survey and point list

    Inventory devices, protocols, register maps, panel space, power and network paths.

  2. 2

    Design and point table sign-off

    Map every point to the target protocol and system; agree it with the client and the upper-system contractor.

  3. 3

    Configuration and FAT

    Build the gateway configuration off site, simulate it and test against the signed point table.

  4. 4

    Installation and wiring

    Mount gateways on DIN rail, wire RS-485 / I/O / Ethernet, apply the IP plan.

  5. 5

    SAT and alarm tests

    Verify values against local readings, test every alarm and command end to end.

  6. 6

    Handover and support

    Hand over configuration backups, point table and as-built documents; train operators.

Müşteriye sağlanan değer

  • Abnormal conditions seen early, before they become failures
  • Reliable trend data for optimisation and fault diagnosis
  • Alarms reach the right person by SMS, email or messaging apps
  • Timestamped records for compliance and reporting

Energy & Power alanındaki diğer çözümler

Projenizi bize anlatın

Protokolleri, nokta sayısını ve hedef sistemi gönderin. Satış ve mühendislik ekibi her başvuruyu birlikte inceler.

Projenizi Görüşelim