Water Quality Monitoring

ปัญหา

pH, turbidity and chlorine are checked by grab samples, so a quality event between samples is found late and records for the regulator are incomplete.

ภาพรวมโซลูชัน

MILESGO gateways collect data from water quality analysers (pH, turbidity, chlorine, DO), 4–20 mA / 0–10 V transmitters, flow meters over Modbus RTU / Modbus TCP, and deliver it to SCADA, a historian / database (MySQL, SQL Server, InfluxDB), SMS, email and messaging alarms as MQTT / OPC UA / Modbus TCP. Field equipment keeps its own protocol and control logic; integration is done by configuration and point mapping, not custom code.

Typical scope

  • water quality analysers (pH, turbidity, chlorine, DO)
  • 4–20 mA / 0–10 V transmitters
  • flow meters

Protocol path

Modbus RTU / Modbus TCP → MQTT / OPC UA / Modbus TCP

Implementation checklist for the project manager

  • Keep sensor calibration certificates on file and plan recalibration intervals.
  • Confirm the authority’s reporting requirements and data formats at the start of the project.
  • Agree data retention and the report format needed for audits with the quality team at the start.
  • For hard-wired signals, list each DI/DO/AI/AO with its type (dry contact, 4–20 mA, 0–10 V, PT1000) and choose I/O modules accordingly.
  • Define an alarm matrix (priority, recipient, escalation) and test every alarm end to end at SAT.
  • Confirm local storage so data survives network outages, and define the retention period.

Project deliverables

  • Signed point table and protocol mapping
  • Gateway configuration files and backups
  • IP address plan and network drawing
  • FAT and SAT test records
  • As-built documentation and operator training

สถาปัตยกรรมระบบ

Field layer: water quality analysers (pH, turbidity, chlorine, DO), 4–20 mA / 0–10 V transmitters, flow meters, connected over Modbus RTU / Modbus TCP. Edge and integration layer: MILESGO protocol gateways and edge controllers, mounted on DIN rail in existing panels, polling each device, time-stamping values and buffering them locally. Upper layer: SCADA, a historian / database (MySQL, SQL Server, InfluxDB), SMS, email and messaging alarms, which receives the data as MQTT / OPC UA / Modbus TCP. Remote access for maintenance runs over VPN rather than open internet ports.

องค์ประกอบของระบบ

Field devices
water quality analysers (pH, turbidity, chlorine, DO), 4–20 mA / 0–10 V transmitters, flow meters
Edge / integration
MILESGO protocol gateways and edge controllers
Upper systems
SCADA, a historian / database (MySQL, SQL Server, InfluxDB), SMS, email and messaging alarms (MQTT / OPC UA / Modbus TCP)
Tools and commissioning
Web-based configuration, point table import/export (Excel), off-site simulation and on-site diagnostic tools

ความสามารถด้านซอฟต์แวร์และ AI

  • Anomaly detection on trend dataอยู่ในแผน
  • Automatic report drafting from collected dataอยู่ในแผน

ขั้นตอนการส่งมอบ

  1. 1

    Site survey and point list

    Inventory devices, protocols, register maps, panel space, power and network paths.

  2. 2

    Design and point table sign-off

    Map every point to the target protocol and system; agree it with the client and the upper-system contractor.

  3. 3

    Configuration and FAT

    Build the gateway configuration off site, simulate it and test against the signed point table.

  4. 4

    Installation and wiring

    Mount gateways on DIN rail, wire RS-485 / I/O / Ethernet, apply the IP plan.

  5. 5

    SAT and alarm tests

    Verify values against local readings, test every alarm and command end to end.

  6. 6

    Handover and support

    Hand over configuration backups, point table and as-built documents; train operators.

คุณค่าสำหรับลูกค้า

  • Timestamped records for compliance and reporting
  • Abnormal conditions seen early, before they become failures
  • Alarms reach the right person by SMS, email or messaging apps
  • Reliable trend data for optimisation and fault diagnosis