Hospitality, Retail & CommercialS83

Hotel HVAC Energy Management

ปัญหา

HVAC is the largest energy use in a hotel, yet chiller plant, VRF and room units are not metered or trended, so savings depend on staff remembering to switch things off.

ภาพรวมโซลูชัน

MILESGO gateways collect data from chillers, VRV / VRF air conditioning systems, fan coil units (FCU), BTU / heat meters, electricity meters over BACnet/IP / Modbus RTU / M-Bus, and deliver it to the energy management system, the BMS, large-screen dashboards (HDMI) as BACnet/IP / MQTT. Field equipment keeps its own protocol and control logic; integration is done by configuration and point mapping, not custom code.

Typical scope

  • chillers
  • VRV / VRF air conditioning systems
  • fan coil units (FCU)
  • BTU / heat meters
  • electricity meters

Protocol path

BACnet/IP / Modbus RTU / M-Bus → BACnet/IP / MQTT

Implementation checklist for the project manager

  • Daikin VRV systems connect through the HBS converter; for other brands confirm the manufacturer’s gateway or interface.
  • Record CT ratios, meter IDs and multipliers in the point table; wrong multipliers are the usual cause of billing errors.
  • Write the control sequence (start/stop order, interlocks, set-points, fallback on communication loss) and have it approved before programming.
  • Commission in read-only mode first; enable write / control points only after the client approves each one.
  • Agree KPI definitions (for example OEE components or kWh per unit) with operations before building dashboards.
  • Hand over configuration backups, point table, IP plan and as-built drawings, with a short operator training.

Project deliverables

  • Signed point table and protocol mapping
  • Gateway configuration files and backups
  • IP address plan and network drawing
  • FAT and SAT test records
  • As-built documentation and operator training

สถาปัตยกรรมระบบ

Field layer: chillers, VRV / VRF air conditioning systems, fan coil units (FCU), BTU / heat meters, electricity meters, connected over BACnet/IP / Modbus RTU / M-Bus. Edge and integration layer: MILESGO protocol gateways and edge controllers, mounted on DIN rail in existing panels, polling each device, time-stamping values and buffering them locally. Upper layer: the energy management system, the BMS, large-screen dashboards (HDMI), which receives the data as BACnet/IP / MQTT. Remote access for maintenance runs over VPN rather than open internet ports.

องค์ประกอบของระบบ

Field devices
chillers, VRV / VRF air conditioning systems, fan coil units (FCU), BTU / heat meters, electricity meters
Edge / integration
MILESGO protocol gateways and edge controllers
Upper systems
the energy management system, the BMS, large-screen dashboards (HDMI) (BACnet/IP / MQTT)
Tools and commissioning
Web-based configuration, point table import/export (Excel), off-site simulation and on-site diagnostic tools

ความสามารถด้านซอฟต์แวร์และ AI

  • Consumption baseline and deviation alertsนำร่อง
  • Load and consumption forecastingอยู่ในแผน

ขั้นตอนการส่งมอบ

  1. 1

    Site survey and point list

    Inventory devices, protocols, register maps, panel space, power and network paths.

  2. 2

    Design and point table sign-off

    Map every point to the target protocol and system; agree it with the client and the upper-system contractor.

  3. 3

    Configuration and FAT

    Build the gateway configuration off site, simulate it and test against the signed point table.

  4. 4

    Installation and wiring

    Mount gateways on DIN rail, wire RS-485 / I/O / Ethernet, apply the IP plan.

  5. 5

    SAT and alarm tests

    Verify values against local readings, test every alarm and command end to end.

  6. 6

    Handover and support

    Hand over configuration backups, point table and as-built documents; train operators.

คุณค่าสำหรับลูกค้า

  • Consumption visible by area, system and time period
  • Reliable trend data for optimisation and fault diagnosis
  • Consumption attributable by tenant, department or cost centre
  • New equipment integrated by configuration, not custom driver development