MILESGO
Poproś o wycenę

Healthcare & EducationS73

Negative Pressure Room Monitoring

Problem

Isolation rooms depend on a pressure difference that can be lost when a door is left open or a fan fails, and staff outside the room are not told.

Opis rozwiązania

MILESGO gateways collect data from differential pressure sensors, door contacts, air handling units (AHU), run/stop and fault dry contacts over Modbus RTU / BACnet MS/TP, and deliver it to the BMS, SMS, email and messaging alarms, WEB HMI panels as BACnet/IP / MQTT. Field equipment keeps its own protocol and control logic; integration is done by configuration and point mapping, not custom code.

Typical scope

  • differential pressure sensors
  • door contacts
  • air handling units (AHU)
  • run/stop and fault dry contacts

Protocol path

Modbus RTU / BACnet MS/TP → BACnet/IP / MQTT

Implementation checklist for the project manager

  • Monitoring does not replace certified medical or safety alarm systems; keep them in place and treat MILESGO data as supervisory.
  • Keep sensor calibration certificates on file and plan recalibration intervals.
  • For hard-wired signals, list each DI/DO/AI/AO with its type (dry contact, 4–20 mA, 0–10 V, PT1000) and choose I/O modules accordingly.
  • Define an alarm matrix (priority, recipient, escalation) and test every alarm end to end at SAT.
  • Agree data retention and the report format needed for audits with the quality team at the start.
  • Confirm DIN-rail space and a stable 12–24 V supply in each panel; use UPS-backed power for critical monitoring.

Project deliverables

  • Signed point table and protocol mapping
  • Gateway configuration files and backups
  • IP address plan and network drawing
  • FAT and SAT test records
  • As-built documentation and operator training

Architektura systemu

Field layer: differential pressure sensors, door contacts, air handling units (AHU), run/stop and fault dry contacts, connected over Modbus RTU / BACnet MS/TP. Edge and integration layer: MILESGO protocol gateways and edge controllers, mounted on DIN rail in existing panels, polling each device, time-stamping values and buffering them locally. Upper layer: the BMS, SMS, email and messaging alarms, WEB HMI panels, which receives the data as BACnet/IP / MQTT. Remote access for maintenance runs over VPN rather than open internet ports.

Skład systemu

Field devices
differential pressure sensors, door contacts, air handling units (AHU), run/stop and fault dry contacts
Edge / integration
MILESGO protocol gateways and edge controllers
Upper systems
the BMS, SMS, email and messaging alarms, WEB HMI panels (BACnet/IP / MQTT)
Tools and commissioning
Web-based configuration, point table import/export (Excel), off-site simulation and on-site diagnostic tools

Możliwości oprogramowania i AI

  • Anomaly detection on trend dataW planach

Etapy wdrożenia

  1. 1

    Site survey and point list

    Inventory devices, protocols, register maps, panel space, power and network paths.

  2. 2

    Design and point table sign-off

    Map every point to the target protocol and system; agree it with the client and the upper-system contractor.

  3. 3

    Configuration and FAT

    Build the gateway configuration off site, simulate it and test against the signed point table.

  4. 4

    Installation and wiring

    Mount gateways on DIN rail, wire RS-485 / I/O / Ethernet, apply the IP plan.

  5. 5

    SAT and alarm tests

    Verify values against local readings, test every alarm and command end to end.

  6. 6

    Handover and support

    Hand over configuration backups, point table and as-built documents; train operators.

Korzyści dla klienta

  • Alarms reach the right person by SMS, email or messaging apps
  • Timestamped records for compliance and reporting
  • Abnormal conditions seen early, before they become failures
  • Reliable trend data for optimisation and fault diagnosis

Więcej rozwiązań w obszarze Healthcare & Education

Opowiedz nam o swoim projekcie

Prześlij protokoły, liczbę punktów i system docelowy. Każde zgłoszenie analizuje zespół handlowo-inżynierski.

Omów swój projekt