Battery Energy Storage Monitoring (BESS)
The problem
The battery BMS, PCS, meters and container HVAC report separately, so the operator has no combined view of state of charge, cell temperature and cooling when an alarm occurs.
Solution overview
MILESGO gateways collect data from battery management systems (BMS) of storage units, power conversion systems (PCS), electricity meters, temperature and humidity sensors, smoke detector contacts over Modbus TCP / Modbus RTU, and deliver it to SCADA, a cloud platform (MQTT), the utility SCADA (IEC 104 / IEC 61850), SMS, email and messaging alarms as MQTT / IEC 60870-5-104 / OPC UA. Field equipment keeps its own protocol and control logic; integration is done by configuration and point mapping, not custom code.
Typical scope
- battery management systems (BMS) of storage units
- power conversion systems (PCS)
- electricity meters
- temperature and humidity sensors
- smoke detector contacts
Protocol path
Modbus TCP / Modbus RTU → MQTT / IEC 60870-5-104 / OPC UA
Implementation checklist for the project manager
- Any set-point control of PV or storage must follow the grid-connection requirements; start with monitoring only.
- Commission in read-only mode first; enable write / control points only after the client approves each one.
- Collect register maps and protocol documents from every equipment vendor early; a missing map is the most common delay.
- Define an alarm matrix (priority, recipient, escalation) and test every alarm end to end at SAT.
- Keep OT networks segregated and use VPN for remote access instead of opening ports to the internet.
- Confirm local storage so data survives network outages, and define the retention period.
Project deliverables
- Signed point table and protocol mapping
- Gateway configuration files and backups
- IP address plan and network drawing
- FAT and SAT test records
- As-built documentation and operator training
System architecture
Field layer: battery management systems (BMS) of storage units, power conversion systems (PCS), electricity meters, temperature and humidity sensors, smoke detector contacts, connected over Modbus TCP / Modbus RTU. Edge and integration layer: MILESGO protocol gateways and edge controllers, mounted on DIN rail in existing panels, polling each device, time-stamping values and buffering them locally. Upper layer: SCADA, a cloud platform (MQTT), the utility SCADA (IEC 104 / IEC 61850), SMS, email and messaging alarms, which receives the data as MQTT / IEC 60870-5-104 / OPC UA. Remote access for maintenance runs over VPN rather than open internet ports.
System composition
- Field devices
- battery management systems (BMS) of storage units, power conversion systems (PCS), electricity meters, temperature and humidity sensors, smoke detector contacts
- Edge / integration
- MILESGO protocol gateways and edge controllers
- Upper systems
- SCADA, a cloud platform (MQTT), the utility SCADA (IEC 104 / IEC 61850), SMS, email and messaging alarms (MQTT / IEC 60870-5-104 / OPC UA)
- Tools and commissioning
- Web-based configuration, point table import/export (Excel), off-site simulation and on-site diagnostic tools
Software and AI capabilities
- Anomaly detection on trend dataRoadmap
- Load and consumption forecastingRoadmap
Delivery steps
- 1
Site survey and point list
Inventory devices, protocols, register maps, panel space, power and network paths.
- 2
Design and point table sign-off
Map every point to the target protocol and system; agree it with the client and the upper-system contractor.
- 3
Configuration and FAT
Build the gateway configuration off site, simulate it and test against the signed point table.
- 4
Installation and wiring
Mount gateways on DIN rail, wire RS-485 / I/O / Ethernet, apply the IP plan.
- 5
SAT and alarm tests
Verify values against local readings, test every alarm and command end to end.
- 6
Handover and support
Hand over configuration backups, point table and as-built documents; train operators.
Customer value
- One view of all subsystems instead of separate vendor consoles
- Alarms reach the right person by SMS, email or messaging apps
- Reliable trend data for optimisation and fault diagnosis
- Timestamped records for compliance and reporting